Search the most relevant Road tenders
Get Latest Tender notices for Road tenders published by various government and private organizations on 100s of websites and newspapers,
Get complete tender information and 100% accurate details for for Road Tenders
Download all Tender documents, RFP, RFQ and more for Road Tenders
Use our advanced filter to find perfect Road Tenders by Organization, Tender value, Opening and Closing date, etc.
TID : 84987747 Dept Tender Number : Tender Type :Contract
Name of Work: Supply, delivery, installation, commissioning of Submersible Pumping machinery with other allied electro-mechanical accessories - Dismantling the installed starters, main switches, cables, damaged stabilizer & internal wirings etc. part by part by hiring electrician as per direction of E.I.C., "Supply and delivery of following materials at site:-, Submersible pumping machinery directly coupled with submersible motor at 415 V (± 10%), 50(± 3%) Hz., Material of Construction :, Pump bowl : Housing : C.I., Pump / Motor shaft : SS-410. , Impeller : Bronze/CS/SS, NRV Size: 65 mm, Starting Method : S/D, Speed : 2900 rpm max. , This item will be procured based on yeild test report of T/W and best efficiency point as per direction of EIC. , (Test certificate, H&Q characterstic curve should be provided at the time of delivery) Pump shall be of 3 star BEE rating as per current schedule of the Bureau of Energy Efficiency (Revision 04, Schedule 7 w.e.f. 01.02.2020) , Make :- As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest ammendments., For T/W no.II, Discharge(Q) - 17m3/hr and Head (H) - 80mtr., ", "80mm dia UPVC (Standard type) Column pipe with both side threaded and one side socketed ( For T/W No. II), a)3 Mtr. Long ", b)1.5 mtr Long , c) Top Adoptor(CI), d) Bottom Adoptor (C.I), "M.S fabricated split type suitable tube well cover as per tube well housing with necessery clamping arrangement with including holes with column pipe , air pipe and cable entry etc. , ( For T/W No. II)", "102 mm. dia 0-10 kg/cm² range wall mounted bourden type glycerine filled pressure gauge complete for tubewell outside the pump house including brass cock & fittings., Make :- As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest ammendments., ( For T/W No. II)", "102 mm. dia. wall mounted bourden type glycerine filled depth gauge with suitable dia. and length of steel air pipe with all fittings including supply of one good quality Hand pump for tubewell outside the pump house. (This cost includes 15 mm. dia. G.I. Pipe approx. 90 ft. length and specials), Make :- As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest ammendments., ( For T/W No. II )", "Anti-snapping safety device for above pump by supplying 1'' dia. Nylone rope of required length (double) including supply of all necessary materials as required. , ( For T/W No. II)", "M.S suspention clamp with necessery nuts, bolts & washer etc suitable for 80 mm dia pipe ( Size 500 mm X 80 mm X 8 mm each), ( For T/W No II)", "80 mm dia, P.N. 1.0, CIDF Non return valve conforming to IS: 5312, part-I. , Make :- As per approved vendor list of PHED vide no. 8864/79/F/2019 dated 28.06.24 with latest ammendments., , ( For T/W No. II )", "80 mm dia, PN-1.0, CIDF sluice valve (non-rising) conforming to IS:14846. , Make :- As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest ammendments., , ( For T/W No. II)", "80 mm dia, (PN-1.0) CIDF, wafer type butterfly Valve operated by three phase actuator conforming to IS:13095/1991, IP 68 , Make :- As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest ammendments., ( For T/W No. II)", "80 mm dia heavy type suitable length CI/MS Black pipes (for delivery header, backwash line for pump under sl no-1, along with necessary bends, specials, fittings , viz flanges, bolts, nuts, gaskets, concentric enlarger , MS dismenteling joint, for connecting main pipe line etc. including providing MS/Bricks/PCC support for laying of pipes, valves as required to make the installation complete. (This includes the cost of supply, delivery of common header & short piece of required length to connect the delivery pipe line), ( For T/W No. II)", "1.1 KV grade, 2.5 sq.mm. 3 core PVC insulated & sheathed copper flat submersible cable. Make :- As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest ammendments., (Supply of items as per site requirement), ", "1.1 KV Grade 415 V, 4 core 16 sq.mm. PVC sheathed XLPE insulated Al. armoured cable conforming to IS:7098 (PART-1) 2011 with latest amendmends as applicable., Make :- As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest ammendments., (Supply of items as per site requirement)", "1.1 KV grade, 12 core, 1.5 sq. mm. Copper Control Cables, Solid Copper Conductor & Balance Stranded Copper, XLPE Insulated PVC Innersheathed, Armoured exruded PVC Type ST2 Sheathed as per IS 7098 (Part 1) 1988. (For actuator connection from panel), Make :- As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest ammendments., (Supply of items as per site requirement), ", "415 V, Three phase PLC Panel with minimum 2mm thickness and degree of protection IP-54, conforming to IS-8623 with suitable Bus bar, Digital Voltmeter, Digital Ammeter, Contactor, delay timer, MCB, Valve Actuator starter etc. with PLC Logic & UPS . i)7.5 -12.5 HP with SDS (star , delta starter) , (Drawing & Bill of material shall be approved by E.I.C) Make :- As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest ammendments. , SPEC: As per Specification attached, ( For T/W No.II)", "15 KVA, 3 phase oil cooling type servo motor operated Voltage Stabilizer, having unbalance 200 - 500 V input voltage, and 415(±1%) output voltage , Auto/manual servo voltage stabilizer with U/V, O/V, O/L protection with MCB at output side, input MCCB, Ammeter Bell etc. as per I.E rules and as per instruction of EIC. Make :- As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest ammendments., ( For T/W No. II)", "Hard wooden board (450mm X 304.8 mmx 25 mm thick), ( For T/W No. II) ", "100Amp, 240/415 V Porcelain fuse unit (Base & Bridge) , Make :- As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest ammendments., (For T/W No.II )", "100 Amps, 415 V, ICTPN (Iron Claded Triple Pole Neutral) main switch in sheet steel enclosure having rewireable type fuse grip. , Make :- As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest ammendments., (For T/W No. II)", "100 Amps, 415 V Bus-Bar chamber having 4 nos. Copper Bar. Make :- As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest ammendments., (For T/W No. II) ", "100 Amp, 4 pole on load change over switch Make :- As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest ammendments., (For T/W No. II)", "Supply and installation of 2 mm thick, powder coated anticorosive painted G.I. Fabricated outdoor mounted kenopy type Cable Jointing Box having four legs and six nos. 100 Amps Al Bus bar, hinje type front having IP 55 protection & locking arrangement as per direction of E I C ., (For T/W No. II)", "LED street light luminarie IP 66 LM6-HPDC Housing Street light aerodynamically designed with better thermal management/ Potted driver is to be provided, the luminaire and housing should be from the same manufacturer(cat no- BRP052 LED 045 CW SLMR FG S1 PSU GR , System Efficacy greater than 100 lumen/watt) Make-Philips OR Equivalent and same techinal specification of Havells.The manufacturer has to provide LM79/LM80 reports corresponding to the luminaire/LED Chip along with type test Certificate.Respectively the luminaire manufacturer should have an in house NABL Accredited testing facility., (For T/W No. II)", "Installation of the above supplied item:-, Installation, testing & commisioning of above supplied Pumping Machinery , MCC, valves etc. (item no. 2 to 15, 19-25 ) by jointing submersible cable within the tubewell situated outside the pump house by making derrick arrangement by assembling the column pipes properly and fitting, fixing the pressure gauge, depth gauge, air pipe etc. in position and erection of delivery line at Jhargram,West Bengal,India